ACS 863 – air conditioning service unit with integrated refrigerant identifier for R1234yf
Robust, yet very manoeuvrable, the ACS 863 fully-automatic service unit is best in class for R1234yf air conditioning service units. It adheres to the highest requirements for servicing commercial vehicles, trucks and hybrid A/C systems, meeting German car manufacturer specifications, SAE and European standards.
The ACS 863 has been designed to make life easier in the workshop, enabling quick, reliable service and maintenance and brings a range of functions to your fingertips.
More Information
Video cannot be shown without your consent
Video: The new Bosch ACS 753 and ACS 863 AC service units for efficient maintenance and repair.
- Deep Recovery function with 99% of the refrigerant able to be recovered within minutes: Cutting time and costs while protecting the environment
- 170 litres/minute vacuum pump: For fast, deep, high performance system cleaning
- Swivelling control console: For ultimate convenience
- Operation is supported with multi-language shortcut help messages: For clear instruction
- Supports both PAG and POE oil types and hoses flushing function: Providing versatility
- Wireless connectivity with seamless connection to Bosch Connected Repair or other workshop networks: Helping you work more efficiently
- Smartphone app: For real-time updates and control at your fingertips
- Innovative oil injection system with refillable, sealed design, which supports both e-vehicle and conventional A/C systems: Reduces risk of contamination
- The modular build and single-service hatch: Access to all vital service components at once, reducing maintenance time
- Integrated leak detection system for inert gas, covering Nitrogen and Formiergas: Provides comprehensive AC system check.
Operating mode | Fully automatic and single function |
Operating mode
Refrigerant
|
Fully automatic and single function
R1234yf
|
Operating mode
Refrigerant recovery
|
Fully automatic and single function
Automatic
|
Operating mode
Recovery accuracy / performance
|
Fully automatic and single function
> 99 %
|
Operating mode
Refrigerant analysis
|
Fully automatic and single function
Embedded
|
Operating mode
Oil recovery
|
Fully automatic and single function
Automatic with electronic scale
|
Operating mode
Vacuum
|
Fully automatic and single function
Automatic
|
Operating mode
Leak test
|
Fully automatic and single function
Automatic
|
Operating mode
Oil injection
|
Fully automatic and single function
Automatic with electronic scale
PAG / POE injection |
Operating mode
UV dye injection
|
Fully automatic and single function
Yes, automatic
|
Operating mode
Refrigerant charge
|
Fully automatic and single function
Automatic with electronic scale
|
Operating mode
Refrigerant charge accuracy
|
Fully automatic and single function
± 15 g
|
Operating mode
Flushing function
|
Fully automatic and single function
Avalaible with optional kit
|
Operating mode
Printer
|
Fully automatic and single function
Embedded
|
Operating mode
Air purge system
|
Fully automatic and single function
Automatic, electronic control
|
Operating mode
A/C hybrid system compatibility
|
Fully automatic and single function
Yes
|
Operating mode
A/C system database
|
Fully automatic and single function
Embedded
|
Operating mode
User database
|
Fully automatic and single function
Yes
|
Operating mode
A/C system performance test
|
Fully automatic and single function
Yes
|
Operating mode
Inert gases leak detection
(N₂, H₂, N₂, Nox, …) function |
Fully automatic and single function
Yes
|
Wireless workshop network connection |
Asanetwork Bosch Connected Repair |
Wireless workshop network connection
Remote control from mobile
|
Asanetwork Bosch Connected Repair
Yes
|
Wireless workshop network connection
HP & LP panel valves
|
Asanetwork Bosch Connected Repair
None
|
Wireless workshop network connection
HP & LP pressure gauges
|
Asanetwork Bosch Connected Repair
Yes, pulse-free
|
Wireless workshop network connection
Internal tank pressure gauge
|
Asanetwork Bosch Connected Repair
Digital
|
Wireless workshop network connection
Service hoses and couplers
|
Asanetwork Bosch Connected Repair
2.5 m (extension: optional)
|
Wireless workshop network connection
Display
|
Asanetwork Bosch Connected Repair
Colour display 7”
(800 x 480 pixels) Colour depth 16 M |
Wireless workshop network connection
Compressor
|
Asanetwork Bosch Connected Repair
1/4 HP
|
Wireless workshop network connection
Vacuum pump
|
Asanetwork Bosch Connected Repair
Dual stage 170 l/min
|
Wireless workshop network connection
Refrigerant tank capacity
|
Asanetwork Bosch Connected Repair
19,4 kg (usable)
|
Wireless workshop network connection
IN oil tank
|
Asanetwork Bosch Connected Repair
2 x 250 ml
(Sealed bottles with piston) |
Wireless workshop network connection
OUT oil tank
|
Asanetwork Bosch Connected Repair
1 x 250 ml
|
Wireless workshop network connection
UV tank
|
Asanetwork Bosch Connected Repair
1 x 250 ml
(Sealed bottles) |
Wireless workshop network connection
Inert gases leak detection
(N₂, H₂, N₂, Nox, …) kit |
Asanetwork Bosch Connected Repair
Optional
|
Wireless workshop network connection
Wireless kit - dongle
|
Asanetwork Bosch Connected Repair
Included
|
Wireless workshop network connection
Operating Temperature
|
Asanetwork Bosch Connected Repair
+10 °C / + 50 °C
|
Wireless workshop network connection
Storage and Transport Temperature
|
Asanetwork Bosch Connected Repair
-20 °C / + 60 °C
|
Wireless workshop network connection
Power Supply
|
Asanetwork Bosch Connected Repair
230 V 50/60 Hz
|
Wireless workshop network connection
Power
|
Asanetwork Bosch Connected Repair
< 1100 W
|
- Safety kit (glasses and gloves)
- Original instructions
- High pressure service hose 1)
- Low pressure service hose 1)
- 1 x New oil tank PAG 250ml
- 1 x New oil tank POE 250ml
- 1 x UV contrast fluid tank 250ml
- Oil drain tank 250ml
- Tank adapter (1234 <22 HW)
Segment Brochure (PDF)
|
|
Fact Sheet (PDF)
|
|